Battery powered datalogger for external CO2 probe up to 10 000ppm and inputs for connecting up to three temperature and/or humidity probes.
Multilogger can be installed permanently to Ethernet network or work as portable devices.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
TECHNICAL DATA
MEASURED VALUE
- Temperature
- Relative humidity
- Counted values (dew point…)
- CO2
TEMPERATURE SENSOR - EXTERNAL PROBE PT1000
- Measuring range -200 to +600 °C
- Accuracy ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C - ±0.2 % from reading from +100 to +600 °C
- Resolution 0.1 °C
TEMPERATURE+HUMIDITY SENSOR - EXTERNAL PROBE T+RH DIGI
- Measuring range according to the connected probe Digi/M
- Accuracy according to the connected probe Digi/M
- Resolution 0.1 °C
DEW POINT
- Measuring range according to the connected probe Digi/M
- Accuracy according to the connected probe Digi/M
- Resolution 0.1 °C
CO2 SENSOR 10.000PPM (OPTIONALLY)
- Measuring range 0 to 10.000 ppm
- Accuracy 100 ppm + 5% of the measured value at 23 °C a 1 013 hPa
GENERAL TECHNICAL DATA
- Operating temperature -10 to +60 °C
- Channels 3x external temperature probe or connectable temperature+humidity probe, 1x external CO2 sensor
- Counted values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Memory 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
- Recording interval 1s to 24 hours
- Display and alarm refresh each 10 s
- Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new - cyclic - after filling memory oldest data is overwritten by new
- Available temperature units degrees Celsius, degrees Fahrenheit
- Communication interface Ethernet, USB, RS232
- Ethernet communication protocols WWW, SNMPv1, XML, DATALINK
- Alarm protocols E-Mail
- Power AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)
- Battery life 3 - 4 weeks
- Protection class IP20
- Dimensions (without connectors) 178 x 95 x 37mm, without attached cables
- Weight (including batteries) approx. 380 g
- Warranty 3 years
FEATURES DESCRIPTION:
* the features may vary depending on the device type
- up to 6 hardware inputs for measuring and recording, 16 virtual channels for temperature, humidity, dew point, atmospheric pressure, current 0 - 20 mA and voltage 0 - 10 V (-60 to 140 mV), two-state events, pulses, CO2
- memory for 1 million values
- indication of alarm conditions via e-mail, SMS, integrated acoustic siren LEDs, stwo-state output to control other devices
- analytical software for data processing and configuration - COMET Vision
- communication interfaces - USB, RS232 and Ethernet (SNMPv1 and XML)
UP TO 4 PHYSICAL INPUTS - 2X TERMINALS + 2X MINIDIN
- Sensors with woltage output (range 0-10 V; accuracy ±10 mV)
- Sensors with current output (range 0-20 mA; accuracy ±20 µA)
- Devices with two-state output (potential-less contact or voltage signal 0-30V); may be applied to input 3 and 4
- Devices with pulse signal (potential-less contact or voltage signal 0-30V); may be applied to input 4
- Temperature probes Pt1000 with built-in configuration memory (serie xxx/M)
- Temperature/relative humidity probes with digital output - DigiS/M, DigiL/M, DIGIH/M
- The probes are interchangeable without calibration to a specific device and regardless of the length of the cable. The length of the cable can be 1, 2, 5, 10, 15 meters
- Internal CO2 sensor with range 0-2000 ppm (custom range 0-10.000ppm)
EVALUATION OF UP TO 16 VARIABLES
The measured values are stored in the internal non-volatile memory. Memory capacity is up to 1 million values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when after fulfilling the memory oldest stored values are overwritten by new ones.
Measured values are displayed on the screen with backlight option and the ability to change the size of display digits
POWER SUPPLY
Multilogger can be powered by AC adapter or by rechargeable batteries with charging capability. Batteries are always a part of the device (you can also use standard alkaline AA batteries). Batteries power the device for several months.
While using the AC adapter, the batteries provide backup operations and provide recording and measurement during power failure. Thanks to the Ethernet output the device informs about the failure via e-mail message.
ALARM LIMITS AND ALARM INDICATION
It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).
Alarm signalization can be acoustic (built-in beeper), optical, sending an e-mail alert or an alarm output. The alarm output is for connecting an external audio or visual alarm.
COMMUNICATION INTERFACES
Multilogger is always equipped with USB connector for communication, data analysis and also for charging of the rechargeable batteries.
Included Ethernet interface allows to:
- send an e-mail when an alarm state starts or ends
- use DATALINK: display current values or download values from memory to COMET Database in your PC. Software COMET Database contains many useful tools for data analysis - graphs, tables, statistics, etc.
- simple wireless communication with Wi-Fi TP-LINK router
- third-party applications to read the actual measured values using universal protocols SNMPv1 and XML
- view current measured values using your web browser
OUTPUT ALARM OUT
- Output can be used for controling other devices when alarm is launched, such as external buzzer, telephone dialer etc.
- Type of output - open collector transistor
- Max. switching current - 100 mA
- Max. voltage on output - 24 V
- Auxiliary voltage at terminal - +5 V (only when the mains supply is present)
- Users can receive alarms if the values go outside the paramters set. Alarms are indicated through an internal buzzer , 3 LEDs or email alerts via Ethernet port.
Software
Comet Vision Software (2.2.8080.19661 dbapi 20.1)
Conversions - application for recalculation of values
Others
Terms and Conditions COMET System s.r.o.
Manuals
Instruction Manual
Quick Start Manual
Declaration of Conformity
MIB
Catelogs