Skip to content
Extra 8% OFF Everything Over $99 for EASTER Sale | code: HAPPYEASTER | Expires 4/01 Midnight CST
Extra 8% OFF Everything Over $99 for EASTER Sale | code: HAPPYEASTER | Expires 4/01 Midnight CST

Quick look

  • Used in livestock and crop production, research, education, ventilation, and facility design
  • Handheld, portable environmental meter with onboard data logging and graphing.
  • Measures wind speed / air speed, temperature, humidity, THI, air flow and displays over 10 total environmental parameters on large, hi-res, hi-contrast, graphic display.
  • Optional LiNK connectivity powered by Bluetooth low energy provides wireless communication to mobile devices and computers.
  • Rugged (drop tested to MIL-STD-810G standards), waterproof and dustproof (sealed to IP67 standards).
  • Protective pouch, neck lanyard and Lithium AA battery included.
  • 5-year warranty.

Kestrel 5000AG Livestock Environmental Meter Overview

The Kestrel 5000AG is designed to meet the needs of livestock, agriculture and animal health professionals. Producers, growers, veterinarians, and consultants in every field of agriculture will gain vital information regarding micro-climate conditions needed to maximize performance and profitability. This lightweight, handheld, multi-function meter can be used inside and out for spot measurement of current conditions and also tracks and logs over 10,000 sets of time-stamped data. Clip the Kestrel 5000AG into the custom Kestrel 5 Series Rotating Vane Mount and you have a sturdy weather station that can be left in place for days or weeks.

Heat Stress Management with THI

THI, (Temperature-Humidity Index)  has been used for decades as a measure to classify heat stress risk in many livestock production and transportation operations. This measurement includes both temperature and relative humidity and is a basis for both strategic and tactical management practices which benefit animal health, productivity and well-being. The Kestrel 5000AG calculates and logs on-site THI based on user selection of either the NRC(National Research Council, 1971) or Yousef(Yousef, 1985) accepted THI calculations. Preprogrammed THI zones are available and can aid in identification of heat stress risk category. Objective and accurate site-specific measurements are critical to ensuring a heat stress management strategy that is cost effective; and they're at your fingertips with the 5000AG.

Environmental Measures

  • Air Flow (CFM)
  • Altitude (Barometric)
  • Barometric Pressure
  • Density Altitude
  • Dew Point Temperature
  • Heat Stress Index
  • Relative Humidity
  • Station Pressure (Absolute Pressure)
  • Temperature Humidity Index (THI)
  • Temperature
  • Wet Bulb Temperature (Psychrometric)
  • Wind Chill
  • Wind Speed/Air Speed

Features

  • Backlight - Switchable White/Red
  • Battery Life Indicator
  • Data Log Graph View
  • Data Logging - Adjustable Interval
  • Date & Time
  • Drop-Tested to MIL-STD-810G
  • FREE Kestrel LiNK Apps for Windows & Mac*
  • High Contrast, Sunlight Readable Monochrome LCD Display
  • Integrated Flip Open Impeller Cover
  • Intuitive Tactile Up/Down/Enter Keypad
  • LiNK Wireless Communication - When Option Selected (Bluetooth low energy)*
  • Multilingual Menus (English, French, Spanish, German)
  • Minimum/Maximum/Average Reading
  • Pressure Sensor
  • Relative Humidity Sensor
  • Temperature Sensor (Patented External Isolated)
  • THI Warning Flag - Settable
  • Waterproof to IP67 (3'/1M for 30 minutes)

Includes

  • Battery - 1 x AA
  • Certificate Of Conformity (Spec Sheet)
  • Instructions
  • Lanyard
  • Protective Drawstring Pouch
SENSORS
SENSORS ACCURACY RESOLUTION SPECIFICATION RANGE NOTES
Wind Speed | Air Speed Larger of 3% of reading, least significant digit or 20 ft/min Speed 0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots
1 B*
0.1 F/S*
0.6 to 40.0 m/s
118 to 7,874 ft/min
2.2 to 144.0 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots
0 to 12 B*
2-131.2*
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller
Ambient Temperature 0.9 °F
0.5 °C
0.1 °F
0.1 °C
-20.0 to 158.0 °F
-29.0 to 70.0 °C
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
Relative Humidity 2%RH 0.1 %RH 10 to 90% 25°C noncondensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure 1.5 hPa|mbar
0.044 inHg
0.022 PSI
0.1 hPa|mbar
0.01 inHg
0.01 PSI
25°C/77°F
700-1100 hPa|mbar
20.67-32.48 inHg
10.15-15.95 PSI
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
Compass
1/16th Cardinal Scale
0 to 360° 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.


CALCULATED MEASUREMENTS
MEASUREMENT ACCURACY (+/-) RESOLUTION SENSORS EMPLOYED
Air Density 0.0002 lb/ft3
0.0033 kg/m
0.001 lbs/ft3
0.001 kg/m3
Temperature, Relative Humidity Pressure
Air Flow 6.71% 1 cfm
1 m3/hr
1 m3/m
0.1m3/s
1 L/s
Air Speed, User Input (Duct Shape & Size)
Altitude typical: 23.6 ft/7.2 m
from 750 to 1100 mBar
max: 48.2 ft/14.7 m
from 300 to 750 mBar
1 ft 1 m Pressure, User Input (Reference Pressure)
Barometric Pressure 0.07 inHg
2.4 hPa|mbar
0.03 PSI
0.01 inHg
0.1 hPa|mbar
0.01 PSI
Pressure, User Input (Reference Altitude)
Crosswind & Headwind/Tailwind 7.1% 1 mph
1 ft/min
0.1 km/h
0.1 m/s
0.1 knots
Wind Speed, Compass
Delta T 3.2 °F
1.8 °C
0.1 °F 0.1 °C Temperature, Relative Humidity Pressure
Density Altitude 226 ft
69 m
1 ft 1 m Temperature, Relative Humidity Pressure
Dew Point 3.4 °F
1.9 °C
15-
95% RH. Refer to Range for Temperature Sensor
0.1 °F
0.1 °C
Temperature, Relative Humidity
Evaporation Rate 0.01 lb/ft2/hr
0.06 kg/m2/hr
0.01 b/ft2/hr
0.01 kg/m2/hr
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature)
Heat Index 7.1°F
4.0°C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Moisture Content | Humidity Ratio (“Grains”) 4.9gpp
.7g/kg
0.1 gpp
0.01 g/kg
Temperature, Relative Humidity Pressure
Probability of Ignition (PIG) PIG Accuracy dependent on proximity of inputs to reference table steps. 10% Temperature, Relative Humidity
THI (NRC) 1.5 °F
0.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
THI (Yousef) 2.3 °F
1.3 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Relative Air Density .0.3% 0.1% Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Psychrometric 3.2 °F
1.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) 1.4 °F
0.8 °C
0.1 °F
0.1 °C
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure
Wind Chill 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Wind Speed, Temperature


ADDITIONAL PRODUCT INFO
Display & Backlight Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage & Graphical display Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
data Upload & Bluetooth Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock/Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
Languages English, French, German, Spanish.
Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)

Shipping is fast and FREE across the USA for all orders $199 or more. For more details about shipping see the full shipping page here.

We offer 30 Day Easy Returns. If you decide you don't need a product we'll take it back so long as it is in original and re-saleable condition. See the full details here.

Found a better price online? We'll match it or beat it if we can. 

All you need to do is let us know via phone or email (fulfillment@weatherscientific.com) and we'll let you know what we can do.

You will need to provide evidence of the better price online and it must include any shipping or taxes charged by that site. i.e. It needs to be the total price.

This only applies to new products, it does not apply to used condition products.